Dala fine wire laser micrometer series adopt laser diffraction measurement method. It has two characteristics: simple structure, high accuracy.measurement range:0.03~2.0mm
Product Characteristics
E2 fine wire laser micrometer series adopt laser diffraction measurement method. It has two main characteristics: simple structure, high accuracy.
There is no motor inside, besides, the smart size and simple structure allows easy maintenance work at the later stage.
For fine wire measurement, the smaller the wire ,the more precision of the repeatability. which can reach to ±0.05um.
It is applicable to the measurement of various fine copper wires, enamelled copper wire,,tungsten wire and steel wire.,etc.
Technical parameters
Part No. | E2 | ||||
Measurement range | 0.03~2.0mm | ||||
Repeatability | ±0.0001mm | ||||
Accuracy | ±(0.00024+0.03%*D)mm | ||||
Dimensional | 176*41*136mm | ||||
Power supply | 24V ±10% 40VA | ||||
Working temperature | 0~550℃ | ||||
Storage temperature | 0~60℃ | ||||
Relative humidity | Maximum 85%, no condensation | ||||
Display | LED | ||||
Communication interface | RS485 Modbus-RTU,CAN,WiFi | ||||
Data collection and analysis | touch screen (option) |