D360R series adopted the best solution (laser diffraction )for the diameter and ovality measurement of ultra-fine wines from 0.005 to 0.3mm with an accuracy of ±(0.03+0.03%*D)um, and 0.015 to 1.0mm with an accuracy of ±(0.1+0.03%*D)um. Thanks to no moving parts, the measurement is very accurate over a long service life.
Product Characteristics
1.CCD array sensor ,high accuracy and good repeatability
2.Extremely short exposure time enables measurement accuracy is same on vibrating product
3.No moving parts inside, measurement is accurate over a long service lifetime without making any calibration
4.Easy and convenient data management
Technical parameters
Part No. | D360-1003R(diameter&ovality) D360-1003(diameter) | D360-101R(diameter&ovality) D360-101(diameter) | |||
Measurement range | 0.005~0.3mm | 0.015~1.0mm | |||
Repeatability | ±0.01μm | ±0.04μm | |||
Accuracy | ±0.03μm±0.03%*D | ±0.1μm±0.03%*D | |||
Dimensional (mm) | 277*51*112.5(Without rotation lamping ) 277*185*112.5 | 227*51*112.5(Without rotation lamping ) 227*185*112.5 | |||
Power supply | 24V ±10% 40VA | ||||
Working temperature | 0~40 ℃ | ||||
Storage temperature | 0~60℃ | ||||
Relative humidity | Maximum 95%, no condensation | ||||
Display | LCD display | ||||
Communication port | RS485 | ||||
Data collection and analysis | Support |